Sterkrak logo
Pricelist and terms of trade Size: 3.1MB Polish version

The STERKRAK is designing and production company. We are working in branches: building automatics, industrial automatics, electronics, ventilation and air conditioning. Our modules are applied in central heating instalations, municipal water, boiler automatics, industrial Building Management Systems and others.

Please visit our NEW PRICELIST


CURRENT OFFER
THREE POINT CONTROL MODULE:

Datasheet of the UST21 (83kB) UST21


Relay modules which convert analog input signals 0 - 10V to three-points output signal.

UST21 is functional equivalent of the MCD3 module.

RELAY MODULES:

Datasheet of the USS111 (99kB) USS111
Datasheet of the LMP (133kB) LMP


Devices working as coupling elements between electronic control circuits (for example PLC controllers) with executive devices.

USS111 is functional equivalent of the MCE3 module,

EXTENSION MODULES 1AO / 2DO:

Datasheet of the USS112 (99kB) USS112
Datasheet of the USS112P (100kB) USS112P
Datasheet of the USS121 (98kB) USS121
Datasheet of the USS121P (99kB) USS121P


Two relay modules converting analog input signal 0-10V to appropriate discrete output states.

USS121 is functional equivalent of the MK1+P module.
EXTENSION MODULES 1AO / 3DO:

Datasheet of the USS123 (99kB) USS123
Datasheet of the USS123P (99kB) USS123P
Datasheet of the URAC3 (99kB) URAC3
Datasheet of the URAC3P (101kB) URAC3P


Three relay modules converting analog input signal 0-10V to appropriate discrete output states.

USS123 is functional equivalent of the MCAS3-3 module.
EXTENSION MODULES 1AO / 6DO:

Datasheet of the URAC6 (127kB) URAC6
Datasheet of the URAC6NZ (128kB) URAC6NZ
Datasheet of the URAC6OC (55kB) URAC6OC
Datasheet of the USS136 (126kB) USS136
Datasheet of the USS136NZ (127kB) USS136NZ
Datasheet of the USS136OC (55kB) USS136OC
Datasheet of the MUR16 (135kB) MUR16
Datasheet of the MUR16NZ (127kB) MUR16NZ
Datasheet of the MUR16OC (52kB) MUR16OC


Six relay modules converting analog input signal 0-10V to appropriate discrete output states.

Modules with suffix:
NZ - have relays with SPST-NC contacts,
OC - galvanic separated, transistor outputs.


USS136 is functional equivalent of the MCAS6-6 module.
EXTENSION MODULES 2AO / 6DO:

Datasheet of the MUR26 (51kB) MUR26
Datasheet of the MUR26NZ (50kB) MUR26NZ
Datasheet of the MUR26OC (53kB) MUR26OC


Six relay modules converting two analog signals 0-10V to any digital combination of outputs. Devices are individually programmed on request of the customer considering input voltages, time dependencies, hysteresis, switching thresholds and output logical states.

Modules with suffix:
NZ - have relays with SPST-NC contacts,
OC - galvanic separated, transistor outputs.

BINARY TO ANALOG CONVERTERS
6DI / 1AI:

Datasheet of the URCA6 (118kB) URCA6
Datasheet of the URCA6P (133kB) URCA6P
Datasheet of the URCA6I (87kB) URCA6I



Devices converting six digital signals to one analog output 0-10V.

URCA6P is functional equivalent of the DA6 and MDAC6 modules.
URCA6I galvanic separated - functional equivalent of the MDAC6OP.
ANALOG TO DIGITAL CONVERTERS
1AO / 6DO:

Datasheet of the PAC16 (133kB) PAC16
Datasheet of the PAC16NZ (135kB) PAC16NZ
Datasheet of the PAC16OC (56kB) PAC16OC



Relay modules containing 6-bit analog to digital converters.

Modules with suffix:
NZ - have relays with SPST-NC contacts,
OC - galvanic separated, transistor outputs.
ANALOG TO DIGITAL CONVERTERS
2 x 1AO / 3DO:

Datasheet of the PAC23 (135kB) PAC23
Datasheet of the PAC23NZ (135kB) PAC23NZ
Datasheet of the PAC23OC (55kB) PAC23OC



Relay modules containing two independent 3-bit analog to digital converters.

Modules with suffix:
NZ - have relays with SPST-NC contacts,
OC - galvanic separated, transistor outputs.
TIME DELAY MODULES:

Datasheet of the UWI (35kB) UWI
Datasheet of the UWIS (34kB) UWIS


Devices used to delay of input signals.

UWIS - galvanic separated UWI.
FAN CONTROL MODULES:

Datasheet of the USW22 (95kB) USW22
Datasheet of the USW44 (33kB) USW44


Modules controlling operation of the fan. Powered from 230V AC lines and serve for periodical ventilation of rooms, as well as for short ventilation, for example after turning on the lighting.